ThermGuard® TT401 - Immersion temperature sensor with analog output

  • Temperature transmitter for liquid or gaseous media in the range of 0...10 V or 4 ... 20 mA
  • Available Without display (Available with display as ThermGuard® TT402 (article no. 1370)
  • Suitable for a measuring range of -30 ...150°C
  • Available with 70 mm to 420 mm immersion depth
  • Rugged design for industrial environments, IP65
The product is available immediately.

From 87.60 Excl. VAT

1 × ThermGuard® thermowell
Insertion depth
From 11.60 Excl. VAT

The ThermGuard® TT401 is a precise and universally applicable temperature transmitter developed for demanding industrial applications. It ensures the continuous measurement of temperatures and offers easy integration into existing control systems thanks to the analog output (0 ... 10 V and 4 ... 20 mA).

The ThermGuard® TT401 duct temperature sensor is used in a wide range of industrial and HVAC (Heating, Ventilation, and Air Conditioning) applications to monitor and control the temperature inside air ducts, for example:

  • Air conditioning monitoringMonitoring of supply air and exhaust air temperatures in air conditioning systems to ensure optimum conditions for buildings.
  • Ventilation controlRegulation of the air temperature in ventilation systems to ensure an adequate supply of fresh air and minimize energy losses.
  • Heating systemsMeasurement of the temperature in air heating systems to enable efficient heat distribution and a comfortable room temperature.
  • Refrigeration technologyMonitoring the air temperature in refrigeration applications to ensure that the required temperatures are maintained for the storage and transportation of perishable goods.
  • Industrial process controlTemperature control in air ducts adjacent to production processes to ensure the quality and consistency of the end product.
  • Power plantsMonitoring the air supply for combustion control in power plants to optimize efficiency and emission reduction.
  • Laboratories and clean roomsMaintaining specific temperature parameters in laboratories and cleanrooms for experimental consistency and contamination prevention.
  • Vehicle painting and dryingRegulation of the air temperature in drying ducts used for drying paint on vehicles after a painting process.
  • GreenhousesTemperature control in ventilated greenhouses to create optimum growing conditions for plants and save energy.

In all these applications, the ThermGuard® TT401 duct temperature sensor plays a central role in controlling the indoor climate, improving energy efficiency, maintaining the performance of critical processes and extending the service life of systems.

Features and benefits:

  • Precise temperature measurement: With a wide measuring range and high accuracy, the ThermGuard® TT401 is ideal for monitoring sensitive processes.
  • Simple installation: Thanks to its compact design and intuitive configuration options, the device can be easily integrated into various environments - even in environments up to PN63 using a separately available immersion sleeve
  • Long-term stability: The TT401 has a robust design that ensures reliable performance even under tough operating conditions.
  • Attractive price-performance ratio: The ThermGuard® TT401 can be used universally as a low-cost temperature transmitter.
  • Customized support: Our dedicated support team provides excellent service and assistance to meet your requirements.

Installation

The duct temperature sensor can be inserted directly into the medium. Alternatively, the use of a Thermowell (please select approx. 20 mm shorter than the sensor) so that you can also replace and maintain the sensor during operation.

If you require the immersion sensor with display, we are happy to refer you to the ThermGuard® TT402 with otherwise identical properties.

On request, we will be happy to provide you with a factory certificate 2.2 in accordance with EN10204 or an acceptance test certificate 3.1 free of charge.

Please configure the desired measuring range (-30 ... 150°C), analog output (4 ... 20 mA or 0 ... 10 V) and immersion depth (70 to 420 mm) according to your requirements.

Additional information
Temperature measuring range

, , ,

Insertion depth

, , , , , ,

Display

Sensor element type

Device type

Load resistance

,

Insulation resistance

, ,

Ambient Temperatur min. (°C)

Ambient temperature max. (°C)

Material sensor

Material connection head

Maximum pressure

,

Protection class housing

Conformity

Operating Voltage

Ambient humidity

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ThermGuard® TT401 – Eintauchtemperaturfühler mit Analogausgang”

Your email address will not be published. Required fields are marked *

DOWNLOADS

Operating instructions & data sheets

Technical drawings

Certificates and characteristic values

Additional information
Temperature measuring range

, , ,

Insertion depth

, , , , , ,

Display

Sensor element type

Device type

Load resistance

,

Insulation resistance

, ,

Ambient Temperatur min. (°C)

Ambient temperature max. (°C)

Material sensor

Material connection head

Maximum pressure

,

Protection class housing

Conformity

Operating Voltage

Ambient humidity

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ThermGuard® TT401 – Eintauchtemperaturfühler mit Analogausgang”

Your email address will not be published. Required fields are marked *

Subscribe to our newsletter

Shopping cart

Sign in

No account yet?

Shop
Wishlist
0 items Cart
My account

Request product now!

Request your desired product now and receive
Exclusive advice and offers!

We will be happy to call you back: